Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe

Product Details
Customization: Available
After-sales Service: Online Technical Support
Warranty: 1 Year
Manufacturer/Factory & Trading Company
Gold Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Experienced Team
The supplier has 7 foreign trading staff(s) and 5 staff(s) with over 6 years of overseas trading experience
Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
to see all verified strength labels (22)
  • Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
  • Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
  • Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
  • Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
  • Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
Find Similar Products

Basic Info.

Model NO.
HG-YTD
Type
Coating Production Line
Coating
Plating
Substrate
Steel
Certification
ISO
Condition
New
Workpiece
Piston Rod
Diameter Size
20-80mm
Coating Thicness
Min. 15 Microns
Transport Package
Seaworthy Packing
Trademark
HAIGE
Origin
China
Production Capacity
100 Sets

Product Description

Metal Coating Machinery for hydraulic rod and pipe
 
Introduction
The line is for 4 bars simultaneous for dia. 40 mm to 120mm in length from 3 meters to 6.5 meters. The chroming tanks are creating 4 chroming layers on 15-40 microns with a very high corrossion resistance. It mainly consists of automatic loading system, pre-processing system before plating, chromium electroplating system, automatic unloading system, chromium mist purification system, chromic acid mist recovery treatment system and electronic control system.

Main Technical Features
1.1 This system is energy conservative and environment protective and the waste water discharged contains no chromium. Before and after plating, the cleaning water (waste water containing chromium) flows into the waste liquid collecting treatment tank, where the waste liquid is cleaned and treated. When the mother tank level needs replenishing, the treated chrome-containing waste water will be replenished back to the mother tank, which complements the evaporation and decomposition of the plating liquid.
1.2 The exhaust air of this system adopts efficient chromium fog treatment system for purification and absorption, and finally reaches the standard emission. The chromium mist purifying system consists of the suction pipe, the chromic acid recovery device, the fan and the acid fog purifying tower, and the chromium fog purifying tower adopts the twin tower series connection. The suction pipe connects the electroplating tank, the chromic acid recycler, the fan and the acid mist purification tower in series. For gas-liquid separation, the chromic acid fog produced will get into the chromic acid recycler through the pipe under the negative pressure created by the fan. The separated chromic acid liquid directly returns to the waste liquid collecting tank through the pipelines. The separated chromic fog will be cleaned and absorbed in 1 # and 2 # acid mist purification towers. After that, it can reach the discharging standard and will be finally discharged.
1.3 The spacing between the workpiece and the anode is small, the workpiece passes through the anode and advances at a constant speed, so the uniformity of the coating is better in the circle or in the direction of the axis.
1.4 Adopt multi layer chromium plating technology. Chromium plating on chromium has been realized. Thus greatly improving the electroplating efficiency and chromium layer corrosion resistance.
1.5 The device adopts multi-channel through plating technology, which can realize continuous chromium plating of multi bars and greatly improve the plating efficiency of equipment. (for example, 4 bars plated at the same time)

Technical Requirements
Preplating
Requirements
Material Grade CK45
diameter range φ40-φ120mm
length range 3000-6500mm
surface roughness Ra0.20
Straightness 0.1/1000
Postplating Quality chrome layer thickness 15-40 microns
chrome layer hardness min 800HV,chrome layer firmly, no sloughing off
appearance of chrome layer chrome layer: continuous smooth, grain refinement, mirror surface, no part of the non-plated Surface
without pinholes, Chromium tumors, rough, burr, peeling and other defects.

Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe
Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe

More details, welcome your inquiry!
Haige Best Metal Coating Machinery for Hydraulic Rod and Pipe



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier